Search results for "MESH: Magnetic Resonance Spectroscopy"
showing 3 items of 3 documents
Intravoxel incoherent motion diffusion-weighted imaging in nonalcoholic fatty liver disease: a 3.0-T MR study.
2012
International audience; PURPOSE: To compare pure molecular diffusion, D, perfusion-related diffusion, D*, and perfusion fraction, f, determined from diffusion-weighted (DW) magnetic resonance (MR) imaging on the basis of the intravoxel incoherent motion (IVIM) theory in patients with type 2 diabetes with and without liver steatosis. MATERIALS AND METHODS: This prospective study was approved by the appropriate ethics committee, and written informed consent was obtained from all patients. Between December 2009 and September 2011, 108 patients with type 2 diabetes (51 men, 57 women; mean age, 50 years) underwent 3.0-T single-voxel point-resolved proton MR spectroscopy of the liver (segment VII…
Bone marrow fat quantification of osteoporotic vertebral compression fractures: comparison of multi-voxel proton MR spectroscopy and chemical-shift g…
2011
Background Only a few studies have used in/opposed phase method for a quantitative evaluation of fat fraction in the spine. Purpose To compare multivoxel proton MR spectroscopy and chemical-shift gradient-echo MR imaging for bone marrow fat quantification in vertebral compression fractures (VCF). Material and Methods Vertebral marrow fat quantification in fifteen patients was measured at 3.0-T. Multi-voxel proton spectroscopy (MRS) and in/opposed-phase MR imaging using a fat map build with a triple-echo gradient-echo sequence was used. All the patients had benign vertebral collapse. Bone marrow fat content was evaluated by both techniques in compressed (acute or chronic) and in non-compress…
Liver methylene fraction by dual- and triple-echo gradient-echo imaging at 3.0T: Correlation with proton MR spectroscopy and estimation of robustness…
2011
Purpose To assess the systematic errors in liver methylene fraction (LMF) resulting from fat–fat interference effects with dual- and triple-echo gradient-recalled-echo Dual/Triple GRE) sequences and to test the robustness of these sequences after iron overloading. Materials and Methods Forty type-2 diabetic patients underwent LMF measurement by 3.0T 1H magnetic resonance spectroscopy (corrected for T1 and T2 decays) as the reference standard and liver fat fraction (%Fat) measurement by four Dual/Triple GRE sequences with 20° and 60° flip angle (α), corrected for T1 recovery. The same four sequences were repeated in eight patients after ferumoxide injection. Corrections for systematic errors…